ABSTRACT Purpose: To determine the effect of upper blepharoplasty on corneal topography and intraocular lens power calculation using Galilei and IOLMaster. Methods: Thirty patients submitted to upper blepharoplasty from May 2014 to March 2017 at the Hospital Oftalmológico de Sorocaba (São Paulo, Braz...
Astigmatismo,
Blefaroplastia,
Lentes Intraoculares,
Astigmatismo/etiología,
Biometría,
Blefaroplastia/efectos adversos,
Brasil,
Córnea/diagnóstico por imagen,
Córnea/cirugía,
Topografía de la Córnea,
Párpados,
Refracción Ocular,
Implantación de Lentes Intraoculares
ABSTRACT Purpose: To analyze subclinical keratoconus topography indexes using Pentacam and Orbscan-II measurements to identify evidences for seeking sensitive indexes to screen and diagnose subclinical keratoconus. Methods: Fifty healthy participants (50 eyes) and 40 patients with subclinical keratocon...
Estudios de Casos y Controles,
Córnea/diagnóstico por imagen,
Córnea/patología,
Topografía de la Córnea/instrumentación,
Topografía de la Córnea/métodos,
Queratocono/diagnóstico por imagen,
Queratocono/patología,
Estudios Prospectivos,
Valores de Referencia,
Reproducibilidad de los Resultados,
Estadísticas no Paramétricas
ABSTRACT Purpose: To compare the postoperative refractive predictability of IOLMaster 500 and Pentacam HR on the basis of keratometry and anterior chamber depth values in eyes with an indication for multifocal intraocular lens (IOL) implantation. Methods: This was a retrospective study conducted on 118...
Cámara Anterior/diagnóstico por imagen,
Cámara Anterior/patología,
Biometría,
Córnea/diagnóstico por imagen,
Córnea/patología,
Topografía de la Córnea/instrumentación,
Interferometría/instrumentación,
Interferometría/métodos,
Implantación de Lentes Intraoculares/métodos,
Lentes Intraoculares Multifocales,
Facoemulsificación/métodos,
Periodo Posoperatorio,
Valor Predictivo de las Pruebas,
Valores de Referencia,
Refracción Ocular/fisiología,
Estudios Retrospectivos,
Factores de Tiempo,
Resultado del Tratamiento,
Agudeza Visual/fisiología
ABSTRACT Purpose: The aim of this study was to evaluate anterior segment parameters and corneal aberrations in patients with retinitis pigmentosa using Scheimpflug imaging and to compare the findings with those for healthy controls. Methods: This single-center, case-control study included patients diag...
Aberrometría/métodos,
Cámara Anterior/diagnóstico por imagen,
Cámara Anterior/patología,
Estudios de Casos y Controles,
Córnea/anomalías,
Córnea/diagnóstico por imagen,
Córnea/patología,
Paquimetría Corneal/métodos,
Topografía de la Córnea/métodos,
Valores de Referencia,
Retinitis Pigmentosa/diagnóstico por imagen,
Retinitis Pigmentosa/patología,
Estadísticas no Paramétricas
ABSTRACT Purpose: The underlying genetic causes of keratoconus are essentially unknown. Here, we conducted whole-exome sequencing in 2 Brazilian families with keratoconus. Methods: Whole-exome sequencing was performed on 6 keratoconus-affected individuals of 2 unrelated pedigrees from Southern Brazil. ...
ABSTRACT Purpose: We aimed to compare the thickness of anterior sclera, corneal layers, and pre-ocular tear film between patients with primary Sjögren's syndrome and healthy individuals. Methods: Fifty-one patients with primary Sjögren's syndrome and 41 healthy control participants were recruited in ...
Estudios de Casos y Controles,
Córnea/diagnóstico por imagen,
Córnea/patología,
Estudios Transversales,
Valores de Referencia,
Esclerótica/diagnóstico por imagen,
Esclerótica/patología,
Síndrome de Sjögren/patología,
Síndrome de Sjögren/fisiopatología,
Lágrimas/fisiología,
Tomografía de Coherencia Óptica/métodos
Abstract Purpose: To report the prevalence and analyse corneal astigmatism patterns in cataract surgery candidates. Methods: Researchers examined 2136 eyes from 1204 patients for cataract surgery from 1 January to 31 December 2016. All the candidates were evaluated with partial coherence interferometry...
Extracción de Catarata/estadística & datos numéricos,
Prevalencia,
Astigmatismo/epidemiología,
Astigmatismo/fisiopatología,
Córnea/diagnóstico por imagen,
Facoemulsificación/estadística & datos numéricos,
Biometría/instrumentación,
Interferometría,
Longitud Axial del Ojo,
Imagen Óptica/instrumentación,
Cámara Anterior
ABSTRACT Objective: To evaluate the correlation of optical biometry and target with variable ages, anterior chamber depth, axial length, R1/K1 and R2/K2 established by two optical biometry devices in patients with cataract. Methods: The study included the analysis of 348 medical records, from which 503 c...
Estudio Observacional,
Estudios Transversales,
Registros Electrónicos de Salud,
Agudeza Visual,
Catarata/diagnóstico,
Extracción de Catarata/métodos,
Periodo Preoperatorio,
Implantación de Lentes Intraoculares/métodos,
Lentes Intraoculares/normas,
Córnea/diagnóstico por imagen,
Biometría/métodos,
Biometría/instrumentación,
Topografía de la Córnea/instrumentación,
Refracción Ocular/fisiología,
Errores de Refracción/diagnóstico por imagen,
Longitud Axial del Ojo/diagnóstico por imagen,
Cámara Anterior/diagnóstico por imagen,
Reproducibilidad de los Resultados,
Cristalino/diagnóstico por imagen
Resumo A degeneração marginal pelúcida (DMP) é uma ectasia corneana rara. Caracteriza-se por afinamento periférico, sem sinais inflamatórios, tipicamente inferior e bilateral, separado do limbo por área de espessura normal. Há protrusão da córnea acima da área de afinamento, resultando em elev...
Informes de Casos,
Agudeza Visual,
Enfermedades de la Córnea/diagnóstico,
Enfermedades de la Córnea/terapia,
Topografía de la Córnea,
Córnea/diagnóstico por imagen,
Microscopía con Lámpara de Hendidura,
Paquimetría Corneal,
Tomografía,
Queratocono,
Lentes de Contacto
Resumo Introdução: O pterígio é uma proliferação de tecido fibrovascular centrípeta, que avança da conjuntiva bulbar em direção ao centro da córnea. A excisão do pterígio pode causar melhora na acuidade visual. A excisão cirúrgica tem como objetivo atingir uma superfície ocular topografi...