Results: 180

Gel pillow designed specifically for obstructive sleep apnea treatment with continuous positive airway pressure

J. bras. pneumol; 42 (5), 2016
ABSTRACT Objective: To determine whether the use of a gel pillow with side cutouts designed to accommodate a continuous positive airway pressure (CPAP) mask and reduce head temperature improves the efficacy of and adherence to auto-CPAP therapy. Methods: Twenty-three consecutive CPAP-naïve patients wi...

Using an abdominal phantom to teach urology residents ultrasound-guided percutaneous needle placement

Int. braz. j. urol; 42 (4), 2016
ABSTRACT Introduction: To assess the effect of a hands-on ultrasound training session to teach urologic trainees ultrasound-guided percutaneous needle placement. Materials and methods: University of California, San Francisco (UCSF) urology residents completed a time trial, placing a needle into a phant...

Comparing insertion characteristics on nasogastric tube placement by using GlideScopeTM visualization vs. MacIntosh laryngoscope assistance in anaesthetized and intubated patients

Rev. bras. anestesiol; 66 (4), 2016
Abstract Background and objective: This was a prospective, randomized clinical study to compare the success rate of nasogastric tube insertion by using GlideScopeTM visualization versus direct MacIntosh laryngoscope assistance in anesthetized and intubated patients. Methods: Ninety-six ASA I or II pati...

The impact of clinical use on the torsional behavior of Reciproc and WaveOne instruments

J. appl. oral sci; 24 (4), 2016
ABSTRACT Torsional overload is a fracture representative parameter for instruments in single-file techniques. Objective The aim of this study was to assess the influence of clinical use, in vivo, on the torsional behavior of Reciproc and WaveOne instruments considering the possibility that they degrade...

Cost comparison of three kinds of compression therapy in venous ulcer

An. bras. dermatol; 91 (4), 2016
Abstract: Evolution and cost of three types of compression therapy (single layer, multilayer and Unna boot) in patients with venous ulceration were compared. The evaluation lasted two months and used photographic records and instrument based on pressure ulcer scale for healing (PUSH). Treatment with mono...

A prospective multicenter European study on flexible ureterorenoscopy for the management of renal stone

Int. braz. j. urol; 42 (3), 2016
ABSTRACT Purpose The aim of this study was to describe the outcomes and the complications of retrograde intrarenal surgery (RIRS) for renal stones in a multi-institutional working group. Materials and Methods From 2012 to 2014, we conducted a prospective study including all RIRS performed for kidney ...

The "Pelvic Harness": a skeletonized mesh implant for safe pelvic floor reconstruction

Int. braz. j. urol; 42 (3), 2016
ABSTRACT Objectives To evaluate the feasibility, safety and surgical results of skeletonized mesh implants to form a pelvic harness for pelvic floor reconstruction surgery. Study design Patients with advanced pelvic floor prolapse were enrolled to this study. Study model was a kit mesh, reduced to 75...

A randomised crossover trial comparing the Airtraq ® NT, McGrath ® MAC and Macintosh laryngoscopes for nasotracheal intubation of simulated easy and difficult airways in a manikin

Rev. bras. anestesiol; 66 (3), 2016
ABSTRACT OBJECTIVE: Several devices can aid nasotracheal intubation when managing difficult airways. The McGrath MAC and Airtraq NT were compared with a Macintosh laryngoscope when studying the performance of anaesthetists with different levels of experience, in a manikin model of easy or difficult air...

Efficacy and safety of a NiTi CAR 27 compression ring for end-to-end anastomosis compared with conventional staplers: A real-world analysis in Chinese colorectal cancer patients

Clinics; 71 (5), 2016
OBJECTIVES: This study aimed to evaluate the safety and efficacy of a new nickel-titanium shape memory alloy compression anastomosis ring, NiTi CAR 27, in constructing an anastomosis for colorectal cancer resection compared with conventional staples. METHODS: In total, 234 consecutive patients diagnosed...

Use and outcomes of amplatz renal dilator for treatment of urethral strictures

Int. braz. j. urol; 42 (2), 2016
ABSTRACT Introduction Urethral stricture disease is still a major problem in men. Many procedures are available for the treatment of urethral strictures; urethral dilatation is one of the oldest. The blind dilatation of urethral strictures may be a difficult and potentially dangerous procedure. The purp...