Objective: to analyze the stress distribution in a 3D model that simulates second molar mesialization using two different types of mini-implants. Material and Methods: a mandible bone model was obtained by recomposing a computed tomography performed by a software program. The cortical and trabecular b...
The rehabilitation of patients with dental implant-supported restorations is an ideal treatment option in contemporary dentistry. The aim of this review was to compile and to demonstrate the mechanical response during loading condition, on the stress distributions of implant-supported prostheses. The f...
Aim: Evaluate the influence of the cervical margin relocation (CMR) on stress distribution in the lower first molar restored with direct nano-ceramic composite (zenit). Methods: A 3D model of the lower first molar was modeled and used. Standardized mesio-occluso-distal (MOD) preparation consisted in two ...
Este estudo teve como objetivo avaliar o efeito da estrutura dentária
remanescente e dois materiais diferentes de restauração CAD/CAM no
desempenho à fadiga e no modo de falha de pré-molares tratados
endodonticamente restaurados por endocrowns. Um total de 90 pré-molares
superiores foram tratados e...
Introdução: O conhecimento da biomecânica de implantes de diâmetro reduzido indica dimensões seguras para uso clínico. Objetivo: O objetivo do presente estudo foi comparar biomecanicamente implantes de diâmetro regular e reduzido para suporte de próteses implantossuportadas unitárias na região ...
Abstract Objective The present study aims to evaluate the influence of different positioning of the hip femoral prosthesis on the stress and strain over this implant. Methods A femoral prosthesis (Taper - Víncula, Rio Claro, SP, Brazil) was submitted to a stress and strain analysis using the finite el...
Objetive: To compare the stresses and deformations generated on the surrounding bone of the zygomatic implants when using an intra sinusal and extra-maxillary approach, through the finite element method. Material and Methods: Computer aided designs (CADs) were constructed using SolidWorks Software of a s...
Esta tese foi dividida em três partes, sendo que cada uma consistiu estudo independente, com objetivos próprios. Na parte 1, o objetivo foi avaliar a influência do modo de representar a interface osso-OMI (osseointegrada ou não osseointegrada) sobre a previsão do risco de reabsorção óssea peri-im...
O presente estudo teve por objetivo avaliar a resistência à flexão de um pino experimental de fibra de vidro vazado, e a resistência adesiva entre este pino experimental à dentina radicular, associando a utilização de um dispositivo iluminador em fibra óptica, sob o processo de envelhecimento, al...
The current review aimed to compare the mechanical properties and clinical behavior of fiberglass and cast metal posts. It included in-vitro studies, finite element analysis, clinical studies, and systematic reviews that evaluated fiberglass and metal posts with reliable methodologies. The reports in ...