Results: 47

The effect of attachment types and implant level on the stress distribution in a mandibular overdenture: a 3D Finite Element Analysis

Braz. dent. sci; 25 (3), 2022
Objective: The objective of this study was to evaluate the stress distribution in bone-surrounding implants placed in different levels in a mandibular overdenture. Material and Methods: A Computerized Tomography (CT) scan of an edentulous mandible was used to generate the models. Two implants with an int...

Overdentures as an alternative to conventional dentures: a micro-costing analysis for Public Health Service in Brazil

Ciênc. Saúde Colet; 26 (8), 2021
Abstract This study aimed to estimate cost and compatibility with public financial incentives of two technologies for treating the edentulous mandible: lower complete dentures (CD) and overdentures retained by two dental implants (OD). This study consisted of a partial economic evaluation, with a micro-c...

Análisis retrospectivo de implantes para sobredentaduras en maxilar inferior, en el marco de la formación de recursos humanos
Retrospective analysis of dental implants placed in the lower jaw, within the post graduate dental training framework

Objetivo: Evaluar el porcentaje de implantes oseointegrados colocados en pacientes edéntulos para la confección de sobredentaduras inferiores, en el marco de la formación de recursos humanos. Materiales y métodos: Se analizaron las historias clínicas de los pacientes que recibieron dos implantes de...

Observation of the effect on immediate mandibular implant-supported overdenture of micro implant system of Italy

Biosci. j. (Online); 36 (6), 2020
The study was design to investigate the clinical effect of Micro implant system in Italy on immediate mandibular implant-supported overdenture. A total of 192 patients with mandibular edentulous treated in our hospital were randomly divided into 2 groups in which the control group consisted of 96 patient...

Effect of cleanser solutions on the retention force of oring attachment: an in vitro study

Braz. dent. j; 31 (6), 2020
Abstract The aim of this study was to evaluate the effect of cleaning solutions on the retention force of o-ring-type overdenture attachments. The effect of four solutions on nitrile rings were evaluated: Cepacol (C), Cepacol with fluoride (CF), Listerine (L) and 0.05% sodium hypochlorite (SH); deionized...

Evaluation of bite force and masticatory performance: complete denture vs mandibular overdenture users

Braz. dent. j; 31 (4), 2020
Abstract: This cross-sectional observational study with 24 patients evaluated differences in bite force (BF) and masticatory performance (MP) between conventional complete denture (CCD) and implant mandibular overdenture (IMO) users and the correlation between these variables. The BF test was performed b...

Overdenture on dental remaining in oncological patients: case report

Braz. dent. sci; 23 (4), 2020
Head and neck cancer occupy the seventh place among the most common neoplasms in the world, with an annual incidence of approximately 640,000 new cases. Radiotherapy treatment has been highlighted, because there is greater tissue preservation, possibility of regression ...

Endoprótesis total de cadera en personas de 65 años y más con artrosis de cadera con limitación funcional severa: problema de salud N°12
Total hip stenting in people 65 years of age and older with severe functional limitation hip osteoarthritis. Health Problem AUGE N°12

Objetivo: Favorecer el adecuado manejo clínico integral de las personas de 65 años y más, con diagnóstico de artrosis de cadera con limitación funcional severa que serán sometidos a una artroplastia total de cadera. Tipo de pacientes y escenario clínico: Personas de 65 años y más, con diagnóst...

Evaluation of the effect of coating vertex denture lining material with plant oils on microbial growth and hardness

J. oral res. (Impresa); 8 (supl.1), 2019
Aims: To evaluate the effect of surface coating with natural plant oils (Salvia officinalis, ginger and eucalyptus) on Candida growth and the hardness of Vertex denture lining material. Materials and method: Forty five specimens were prepared from soft acrylic lining material, twenty five of which were 1...

Immediate small-diameter implants as abutments for an overdenture in the edentulous atrophic mandible: report of immersion endoscopic bone in vivo, and histologic bone-implant evaluation after 6 months of function

Int. j. morphol; 37 (2), 2019
The aim of this report was to endoscopically evaluate bone quality in vivo in the immediate installation of temporary small-diameter implants, and again after 6 months of function, through an attachments system for overdenture, in the atrophic mandible of a patient. We also histologically evaluated bone-...