Implantation of cardiac electronic devices is an increasingly common technique and the possibility of device dysfunction caused by electrode displacement should be taken into account. We describe the case of an 88-year-old patient with syncopes several months after pacemaker implantation in which a pacem...
SUMMARY OBJECTIVE: Use Lead-DBS software to analyze stereotactical surgical outcome of an operated population and demonstrate that small target deviations do not compromise the stimulation of desired structures, even with small amperages. METHODS: Image exams of patients submitted to deep brain stimu...
Deep brain stimulation has become an option for advanced Parkinson’s disease
treatment since the 1990s, but the first reports are from Benabid’s team, a French
neurosurgeon, in the 1980s. The subthalamic nucleus (STN), more specifically its
dorsolateral portion, is the most commonly stimulated brain ...
Núcleo Subtalámico/diagnóstico por imagen,
Núcleo Subtalámico/cirugía,
Cráneo/anatomía & histología,
Estimulación Encefálica Profunda/métodos,
Procesamiento de Imagen Asistido por Computador,
Espectroscopía de Resonancia Magnética/métodos,
Procedimientos Neuroquirúrgicos/métodos,
Enfermedad de Parkinson/terapia,
Núcleo Rojo,
Hipotálamo Posterior,
Núcleo Interpeduncular,
Electrodos Implantados
ABSTRACT Background: Transcranial direct current stimulation (tDCS) has been investigated in movement disorders, making it a therapeutic alternative in clinical settings. However, there is still no consensus on the most appropriate treatment protocols in most cases, and the presence of deep brain stimul...
Dolor Crónico/terapia,
Estimulación Encefálica Profunda/instrumentación,
Estimulación Encefálica Profunda/métodos,
Trastorno Depresivo/terapia,
Trastornos Distónicos/terapia,
Electrodos Implantados,
Pruebas de Estado Mental y Demencia,
Reproducibilidad de los Resultados,
Factores de Tiempo,
Estimulación Transcraneal de Corriente Directa/instrumentación,
Estimulación Transcraneal de Corriente Directa/métodos,
Resultado del Tratamiento
Resumen: Se presenta el caso de un hombre de 79 años con miocardiopatía dilatada severa, disfunción ventricular izquierda, fibrilación auricular permanente y portador de un resincronizador ventricular. Al efectuar un recambio del resincronizador se implantó un electrodo adicional para estimulación ...
Abstract Background: Few studies have characterized the surgical outcomes following epicardial pacemaker implantation in neonates with congenital complete atrioventricular block (CCAVB). Objective: This study sought to assess the long-term outcomes of a minimally invasive epicardial approach using a su...
Estimulación Cardíaca Artificial/métodos,
Electrodos Implantados,
Diseño de Equipo,
Estudios de Seguimiento,
Bloqueo Cardíaco/congénito,
Bloqueo Cardíaco/cirugía,
Complicaciones Intraoperatorias,
Ilustración Médica,
Procedimientos Quirúrgicos Mínimamente Invasivos/métodos,
Tempo Operativo,
Marcapaso Artificial,
Complicaciones Posoperatorias,
Radiografía Torácica,
Reproducibilidad de los Resultados,
Resultado del Tratamiento
ABSTRACT The Bereitschaftspotential (BP) is a negative wave observed in EEG retrograde averaging, preceding a motor act. The objective was to study the BP preceding voluntary eyelid blinks in Parkinson's disease (PD) patients during off and on phases of levodopa. Methods Ten PD patients in stages 1 and...
Análisis de Varianza,
Antiparkinsonianos/efectos adversos,
Parpadeo/fisiología,
Estudios de Casos y Controles,
Variación Contingente Negativa/fisiología,
Electrodos Implantados,
Electroencefalografía,
Párpados/fisiología,
Hipocinesia/etiología,
Levodopa/efectos adversos,
Corteza Motora/fisiología,
Movimiento/fisiología,
Enfermedad de Parkinson/tratamiento farmacológico,
Enfermedad de Parkinson/fisiopatología,
Factores de Tiempo
Monitores de eventos implantáveis estão cada vez mais presentes em
nossa realidade. Este relato tem como foco o registro eletrocardiográ-
fico obtido por monitor de eventos implantável durante ressonância
magnética de paciente com síncope de repetição. O registro demonstra
traçado interpretado ...
Varela Barca, Laura;
Centella Hernández, Tomasa;
García, Miren Martín;
Redondo Palacios, Ana;
Celemín Canorea, Daniel;
Miguelena Hycka, Javier;
López Menéndez, Jose;
Muñoz Pérez, Rafael;
García Andrade, Ignacio;
Oliva De Anquín, Enrique;
Rodríguez-Roda Stuart, Jorge.
RESUMEN La esternotomía media continúa siendo el gold-standart de abordaje quirúrgico en cirugía cardiaca. Aún realizada correctamente, la apertura media del esternón presenta complicaciones en el 1-5% de los casos que varían en su gravedad desde la infección de la herida quirúrgica a la lesión...