Results: 9

A feasible in vitro method to evaluate bacterial infiltration in three implant-abutment connection systems

J. oral res. (Impresa); 13 (1), 2024
Introduction: Microorganism infiltration through the im-plant-abutment interface causes oral health problems such as periimplantitis, leading to implant loss. Materials and Methods: A feasible new method to quantify the Streptococcus mutans (S. mutans) infiltration through the implant-abutment interface ...

Does subgingival bacterial colonization differ between implants and teeth? A systematic review

Braz. oral res. (Online); 33 (supl.1), 2019
Abstract The aim was of this study was to determine the current weight of evidence for the existence of specific differences between the microbiota of healthy teeth and healthy implants, or of teeth with periodontitis and implants with peri-implantitis. A systematic review was conducted according to the ...

Chemical and Microscopy Characterization of Trans-Endodontic Implants

Odovtos (En línea); 20 (2), 2018
Abstract Trans-endodontic implants are an artificial extension through root apex anchored in periradicular bone tissue. The aim is to improve the crown-root ratio and to provide stability to dental organ present. Zirconium oxide (ZrO2) is a material of great technological importance, having good natural ...

Successful and failed mini-implants: microbiological evaluation and quantification of bacterial endotoxin

J. appl. oral sci; 26 (), 2018
Abstract Objectives Using two groups of mini-implants (successful and failed) the objectives of this in vivo study were: to evaluate the microbial contamination by the checkerboard DNA-DNA hybridization technique and to quantify the bacterial endotoxin by the limulus amebocyte lysate assay. Material a...

Estudio de medidas de control de la colonización microbiana de la cámara interna del implante y del sistema implante-pilar por medio de un estudio in vitro

Odontoestomatol; 19 (n.esp), 2017
Objetivo: Determinar mediante un ensayo in vitro, medidas de control del biofilm en la cámara interna del implante. Método: Se seleccionaron diferentes agentes antimicrobianos que se colocaron en las cámaras de 3 grupos de implantes. Luego de 7 días de inmersos en una suspensión microbiana e incubad...

Gram-negative enteric rods associated to early implant failure and peri-implantitis: case report and systematic literature review

The microbiota associated with failed implants includes Pseudomonas and Gram-negative enteric rods. The present study reports a case of Escherichia coli associated to early implant failed that was resistant in vitro to doxycycline, amoxicillin, metronidazole, and clindamycin, but was susceptible in vitro...

Microbiota Oral Presente en Pacientes Edentulos

El objetivo fue identificar las condiciones orales de pacientes edentulos que acudieron a rehabilitación a la Clínica de Prótesis Total de la Facultad de Odontología de la Universidad Autónoma del Estado de México. El diseño del estudio fue observacional, descriptivo, transversal y prospectivo con...