Leak and Scattering Assessment by Optically Stimulated Luminescence Dosimetry in a Helical Linear Accelerator

Radiation absorbed doses to organs outside the radiation therapy treatment beam can be significant and therefore of clinical interest. Two sets of out-of-beam measurements were performed measuring the leak dose and the scattered dose, at 5 points within the accelerator components (accelerator tube and co...

Characterization of Geiger-Müller radiation detectors response at the University of Costa Rica's Cyclotron Facilities

To ensure a reliable verification of a radiation detector, the right parameters for this response verification must be determined and a specific characterization on the detectors of interest must be performed. These were the main pillars of this study, where four Geiger-Müller at the University of Costa...

Biological X-ray irradiator characterization for use with small animals and cells

Braz. j. med. biol. res; 50 (3), 2017
This study presents the characterization of an X-ray irradiator through dosimetric tests, which confirms the actual dose rate that small animals and cells will be exposed to during radiobiological experiments. We evaluated the linearity, consistency, repeatability, and dose distribution in the positions ...

Digital orthodontic radiographic set versus cone-beam computed tomography: an evaluation of the effective dose

ABSTRACT Objective: The aim of this study was to compare the equivalent and effective doses of different digital radiographic methods (panoramic, lateral cephalometric and periapical) with cone-beam computed tomography (CBCT). Methods: Precalibrated thermoluminescent dosimeters were placed at 24 locat...

Comportamento de monitores portáteis em feixes de radiaçäo X de baixas energias
Behavioral of portable monitors in low energy X-rays fields

No Laboratório de Calibração de instrumentos do IPEN os monitores portáteis são calibrados com radiação gama de (60)Co e (137)Cs; no entanto, sabe-se que muitos destes instrumentos são utilizados para medidas em campos de radiação X até mesmo na faixa em que apresentam dependência energética...

La video-cistometría en el niño
Videocystometry in the child

Rev. chil. urol; 60 (2), 1995
Se estudió un grupo de 121 niños por medio de video-cistometría sincrónica usando un combinador óptimo de imágenes (4) con un promedio de edad de 9.32 años, venidos de todo el país, especialmente la zona central. Para efectos de orden se catalogan las patologías en: -Incontinencia de orina. -Inc...

Levantamento radiométrico em estudos hemodinâmicos com equipamento Siemens Angioskop D

Arq. bras. cardiol; 61 (4), 1993
PURPOSE--To provide data for professional specialized in these subjects, contributing to minimize their exposure radiation dosage. METHODS--We made a radiometric survey using a ionization chamber to check the exposure rate in several places in the examination's room to different operational conditions of...

Combinador óptico de imágenes para la videocistometría sincrónica: descripción técnica
Optical combiner of images for sincronic videocystometry: technical description

Rev. chil. urol; 49 (1), 1986
Se presenta un equipo diseñado por los autores que permite disponer de la visión simultánea de las curvas urodinámicas y de la imagen radiografica del tracto urinario inferior. Tiene la ventaja de un costo reducido en comparación a los equipos comerciales...