Abstract Introduction Kinesio tape (KT), although frequently used in sports, is still a matter of debate, and the results of studies that evaluated its effects on muscle strength (MS) in athletes are still inconclusive and contradictory. Objective To evaluate the effect of a progressive KT tension pr...
Introduction: The development of new biomaterials with improved properties is a trend in regenerative medicine. The successful healing of implants is related to their osseointegration and the topographic geometry of their surface. Treatment with argon plasma acts on the surface of the implants, bringing ...
ABSTRACT Objective: To analyze the transversal and anterior-posterior changes obtained in patients treated only with the Damon system. Material and Methods: 51 patients with either class I or class II division 1 sagittal relationship treated with the Damon system and the same archwire sequence were ret...
Estudios Retrospectivos,
d0160140,
d0089630,
d0016410,
Análisis de Varianza,
Análisis de Regresión,
Cefalometría/instrumentación,
Soportes Ortodóncicos,
Maloclusión Clase I de Angle/diagnóstico por imagen,
Estudios Transversales/métodos,
Torque,
Ortodoncia Correctiva
This article aims to associate patient-reported pain intensity in the immediate seven days after dental implant surgery with surgical factors, sex and patient age. The sample was composed of 108 patients from a dental school in southern Brazilian, between 2018 and 2020. The variables torque, pre- and pos...
Com o aumento da população brasileira e consequentemente o número de edêntulos realizando tratamentos reabilitadores com implantes dentários, se tornou frequente aparições de complicações como, por exemplo, sua fratura. O presente trabalho tem por objetivo apresentar as causas prováveis relacio...
ABSTRACT: The most common failure in implantology are due to mechanical instability. Torque loosening or fracture of the screws are the most frequent complications. Furthermore, the fractured screw retrieval is complicated and time-consuming. So, modifications in the design of implant systems are justifi...
Objetivo: Describir las fallas en diferentes sistemas de
implantes al ser sometidos a fuerzas de torsión creciente, de-
terminar el torque en el cual aparece un daño medible en el
implante o alguno de sus componentes y especificar la falla
más frecuente.
Materiales y métodos: Se realiz...
Silva, Alecsandro de Moura;
Matos, Jefferson David Melo de;
Tribst, João Paulo Mendes;
da Rocha Scalzer Lopes, Guilherme;
da Silva Machado Martinelli, Carolina;
de Souto Borges, Alexandre Luiz;
Tomomitsu Kimpara, Estevão;
Nogueira-Junior, Lafayette;
Marques de-Melo, Renata;
Bottino, Marco Antonio.
The aim of this study was to evaluate the influence of overtorque on integrity, strength and stress on external hexagonal implants (EH), with two different grades (N=10): conventional (C), grade 4; and modified (M), grade 4 with thermal treatment. The dimensions of EH were 3.75 x 13 mm; the specimens wer...
The presence of severe dynamic knee valgus in asymptomatic women may be a factor related to future complaints of pain in this joint. The aim of this study is to correlate the strength levels of hip and trunk stabilizer muscles with knee valgus angles, pelvic and trunk tilt in asymptomatic young women. 22...
Dinamómetro de Fuerza Muscular,
Anamnesis,
Articulaciones,
Dolor,
Fenómenos Biomecánicos,
Heridas y Lesiones,
Fuerza Muscular,
Rodilla,
Movimiento,
Mujeres,
Músculos,
Adulto Joven,
Rotación,
Torque,
Modalidades de Fisioterapia
Objetivo: O objetivo do presente trabalho foi avaliar a resistência à fadiga cíclica e torcional de instrumentos rotatórios de níquel-titânio com secções transversais semelhantes e confeccionados com diferentes tipos de tratamentos térmicos: Hyflex CM (HCM 25/.06), Vortex Blue (VB 25/.06), Seque...