ABSTRACT Objective:
to describe the patients care in the use of the Male External Catheter in Adults in a clinical-surgical hospitalization unit. Method:
a cross-sectional study. Evaluation of 30 patients hospitalized in clinical-surgical units to collect items related to the specific care provided. Results:
100% had no reference to the use of external catheter in the evolution of the nurse; 43.3% of the assistants or technicians recorded; 36.6% presented skin lesions; 100% had a latex device attached with adhesive tape; 90% were not submitted to hair removal; 96.7% had daily genital hygiene; 70% received no guidance at all. Conclusion:
no individualized evaluation was observed for the use of the device, nursing records did not include prescription and description of installation and care, latex device and micropore paper adhesive tape were predominant; skin lesions were prevalent, hygiene and exchange were adequate, few patients were advised regarding the use of the device.
RESUMEN Objetivo:
describir la asistencia a los pacientes en uso del Cateter Urinario Externo Masculino en una unidad de internación clínico-quirúrgica. Método:
estudio transversal. Evaluación de 30 pacientes internados en unidades clínico-quirúrgicas para el levantamiento de ítems relacionados al cuidado específico prestado. Resultados:
el 100% no tuvo referencia del uso de catéter externo en la evolución del enfermero; el 43,3% de los auxiliares o técnicos realizaron anotaciones; el 36,6% presentó lesión de la piel; el 100% estaba con dispositivo de látex fijado con cinta adhesiva; el 90% no fue sometido a la remoción de los pelos; el 96,7% realizó higiene genital diariamente; el 70% no recibió ningún tipo de orientación. Conclusión:
no se observó una evaluación individualizada para el uso del dispositivo, los registros de Enfermería no contemplaron prescripción y descripción de instalación y cuidados; el dispositivo de látex y la cinta adhesiva microporosa fueron predominantes; las lesiones de la piel fueron prevalentes, la higiene y el cambio fueron adecuados, y pocos pacientes fueron orientados en cuanto al uso del dispositivo.
RESUMO Objetivo:
descrever a assistência aos pacientes em uso do Cateter Urinário Externo Masculino em unidade de internação clínico-cirúrgica. Método:
estudo transversal. Avaliação de 30 pacientes internados em unidades clínico-cirúrgicas para levantamento de itens relacionados ao cuidado específico prestado. Resultados:
100% não teve referência do uso de cateter externo na evolução do enfermeiro; 43,3% dos auxiliares ou técnicos realizaram anotação; 36,6% apresentaram lesão de pele; 100% estava com dispositivo de látex fixado com fita adesiva; 90% não foram submetidos à remoção dos pelos; 96,7% tiveram higiene genital diariamente; 70% não receberam nenhum tipo de orientação. Conclusão:
não se observou avaliação individualizada para uso do dispositivo, os registros de enfermagem não contemplaram prescrição e descrição de instalação e cuidados, dispositivo de látex e fita adesiva microporosa foram predominantes; lesões de pele foram prevalentes, higiene e troca foram adequadas, poucos pacientes foram orientados quanto ao uso do dispositivo.