Efecto del uso de protectores puerto desinfectantes para la disminución de las bacteriemias asociadas a catéteres venosos centrales
Effect of the use of antiseptic barrier caps for the reduction of bacteremia associated with central venous catheters
Efeito do uso de protetores desinfetantes portuários para a redução da bacteremia associada a cateteres venosos centrais
Enferm. actual Costa Rica (Online); (38), 2020
Publication year: 2020
Resumen Identificar el efecto del uso de protectores puerto desinfectantes en los conectores sin aguja en la disminución de las bacteriemias asociadas a catéter venoso central. Se realizó una revisión rápida de la literatura a través de una búsqueda de artículos en idiomas inglés y español en Pubmed, Medline, Cochrane Library y Science Direct, de diciembre del año 2018 a febrero del año 2019.
Esta revisión se centró en identificar ensayos:
clínicos aleatorizados, cohorte longitudinal, revisiones sistemáticas y meta-análisis.Los criterios de inclusión fueron:
usuarios hospitalizados, desinfección pasiva con protectores puerto desinfectantes y reporte de disminución de las bacteriemias asociadas a catéter venoso central con su uso. Un total de 2479 artículos se identificaron como potencialmente relevantes; después de eliminar los duplicados, quedaron 1622 artículos, los cuales fueron evaluados según título y resumen. Posteriormente, 59 artículos fueron analizados en texto completo; se seleccionaron 3 artículos correspondientes a tres revisiones sistemáticas, de las cuales dos realizaron metaanálisis. La evidencia disponible sugiere que estudios no aleatorizados han demostrado que el uso de los protectores puerto desinfectantes con alcohol isopropílico al 70% en los conectores sin aguja, puede generar una reducción de las bacteriemias asociadas al catéter venoso central y podría considerarse como una medida costo efectiva; no obstante, se requieren estudios aleatorizados que confirmen estos resultados.
Abstract Identify the effect of the use of disinfectant port protectors on needleless connectors in the reduction of bacteraemias associated with central venous catheters. A quick review of the literature was carried out through a search of articles in English and Spanish in Pubmed, Medline, Cochrane Library and Science Direct; from December 2018 to February 2019. It focused on identifying randomized clinical trials, longitudinal cohort, reviews and meta-analysis.
The inclusion criteria were:
hospitalized users, passive disinfection with disinfectant port protectors and report of decrease in bacteraemias associated with central venous catheter with its use. A total of 2479 articles were identified as potentially relevant, after eliminating duplicates, 1622 articles were evaluated according to inclusion criteria were: hospitalized users, passive disinfection with disinfectant port protectors and report of decrease in bacteraemias associated with central venous catheter with its use. The available evidence suggests that non-randomized studies have shown that the use of disinfectant port protectors with 70% isopropyl alcohol in needleless connectors can lead to a reduction in bacteraemias associated with central venous catheters and could be considered as a cost measure. effective, however, randomized studies are required to confirm these results.
Resumo Identificar o efeito do uso de protetores de porta desinfetantes nos conectores sem agulha na redução de bacteremias associadas aos cateteres venosos centrais. Uma rápida revisão da literatura foi realizada através de uma pesquisa de artigos em inglês e espanhol no Pubmed, Medline, Cochrane Library e Science Direct; de dezembro de 2018 a fevereiro de 2019. Concentrou-se na identificação de ensaios clínicos randomizados, coorte longitudinal, revisões sistemáticas e metanálise.