Rev. colomb. reumatol; 27 (supl.2), 2020
Publication year: 2020
RESUMEN Introducción:
Existen diferentes sistemas de graduación para interpretar la biopsia de glándula salival menor (BGSM) en pacientes con síntomas secos. En la actualidad la metodología recomendada (Focus Score [FS]), aunque no se emplea de forma rutinaria, conlleva discrepancias diagnósticas. Objetivo:
Determinar la concordancia de la lectura histopatológica de BGSM entre las técnicas FS y Chisholm Mason (CM) para el diagnóstico de sialoadenitis linfocítica focal en el hospital de San José, entre enero de 2017 y junio de 2018. Métodos:
Estudio de concordancia. Se incluyeron BGSM de pacientes con síntomas secos. Se excluyó material no apto para el estudio, o con menos de 4 lóbulos o menos de 8 mm de área. Se clasificaron utilizando las técnicas FS y CM por 2 evaluadores independientes. Se evaluó el acuerdo interobservador, intraobsevador y global entre las pruebas mediante el coeficiente de Kappa de Cohen. Resultados:
Se evaluaron 130 biopsias. Los valores K intraobservador entre FS y CM fueron 0,42 para el observador 1 y 0,23 para el observador 2. Los valores K del acuerdo interobservador fueron 0,47 para FS y 0,65 para CM. La concordancia entre los 2 sistemas de puntuación fue K de 0,13. Conclusiones:
Se evidencia una probable sobreestimación de focos con CM, que resalta sus debilidades, y mayor precisión con FS. Por ende, la concordancia entre las 2 pruebas es débil. Es necesario un mayor esfuerzo para el uso del método estandarizado de lectura de BGSM con el FS para una correcta interpretación y beneficio en la clasificación de pacientes con síndrome seco.
ABSTRACT Introduction:
There are different grading systems for interpreting the minor salivary gland biopsy (MSGB) in patients with dry symptoms (Sicca). The recommended methodology is currently the Focus Score (FS), which, although not performed routinely, results in diagnostic discrepancies. Objective:
To determine the concordance of the histopathological reading of MSGB between the FS and Chisholm Mason (CM) techniques for diagnosis of focal lymphocytic sialadenitis at the San José Hospital between January 2017 and June 2018. Methods:
Concordance study. MSGB of patients with sicca symptoms were included. Material not suitable for study and / or with less than 4 lobules and / or less than 8 mm of surface area was excluded. They were classified, using the FS and CM techniques, by two independent evaluators. The inter-observer, intra-observer, and overall agreement between the tests were evaluated using Cohen's Kappa coefficient. Results:
A total of 130 biopsies were evaluated. The intra-observer K values between FS and CM were 0.42 for observer 1, and 0.23 for observer 2. The K values of the inter-observer agreement were 0.47 for FS, and 0.65 for CM. The concordance between the two scoring systems was K = 0.13. Conclusions:
There is evidence of a probable over-estimation of foci with CM, highlighting its weaknesses and greater precision with FS technique, resulting in the weak concordance between the two tests. A greater effort is necessary for the use of the standardised MSGB FS reading method for a correct interpretation and benefit in the classification of patients with dry syndrome.