Coluna/Columna; 20 (4), 2021
Publication year: 2021
ABSTRACT Introduction:
The paravertebral musculature is essential for the biomechanics and stability of the spine, and its involvement in the pathophysiology of spinal diseases has been demonstrated. Qualitative evaluation of muscle degeneration is usually performed by analyzing the fat infiltration rate proposed by the Goutallier classification system. Objective:
The objective of this study is to analyze the intra- and interobserver agreement of the Goutallier Classification for the evaluation of fatty degeneration of the multifidus muscle, using magnetic resonance imaging exams. Methods:
The study included 68 patients, all diagnosed with symptomatic disc hernia and indicated for surgery. Preoperative magnetic resonance images were used for the analyses. The images were initially evaluated by two orthopedists and two medical students, and then re-evaluated after two weeks. Intra- and inter-observer reliability analysis was performed using the Fleiss Kappa test and the Landis and Koch criteria. All the analyses were performed using the R statistical environment (R Development Core Team, version 3.3.1, 2016) and the significance level was set at 5%. Results:
The percentages of intra- and inter-observer agreement were 86.76% and 61.03%, respectively. The intraobserver agreement was near perfect and the interobserver agreement was moderate. Conclusion:
The Goutallier Classification System showed moderate interobserver and intraobserver agreement, being a relevant tool for the evaluation of paravertebral musculature fat replacement. Level of evidence II; Prospective study for diagnostic purposes.
RESUMO Introdução:
A musculatura paravertebral é essencial para a biomecânica e estabilidade da coluna e tem sido demonstrado seu envolvimento na fisiopatologia das doenças da coluna vertebral. A avaliação qualitativa da degeneração muscular é usualmente feita pela análise da taxa de infiltração de gordura proposta pelo Sistema de Classificação de Goutallier. Objetivo:
O objetivo deste trabalho é analisar a concordância intra e interobservador da Classificação de Goutallier para avaliação da degeneração gordurosa do músculo multífido por meio de exames de ressonância magnética. Métodos:
Fizeram parte do estudo 68 pacientes, todos com diagnóstico de hérnia discal sintomática e com indicação cirúrgica. As imagens de ressonância magnética colhidas no pré-operatório foram analisadas por dois ortopedistas e dois estudantes de medicina e foram reavaliadas duas semanas depois. Foi realizada análise de confiabilidade intra e interobservador por meio do teste Kappa de Fleiss e pelos critérios de Landis e Koch. Todas as análises foram realizadas com o auxílio do ambiente estatístico R (R Development Core Team, versão 3.3.1, 2016), e o nível de significância foi fixado em 5%. Resultados:
As porcentagens de concordância intra e interobservadores foram, respectivamente, 86,76% e 61,03%. A concordância intraobservador foi quase perfeita e moderada interobservadores. Conclusões:
O Sistema de Classificação de Goutallier demonstrou concordância moderada interobservador e intraobservador, sendo uma ferramenta relevante na avaliação da substituição gordurosa da musculatura paravertebral. Nível de evidência II; Estudo prospectivo para fins diagnósticos.
RESUMEN Introducción:
La musculatura paravertebral es fundamental para la biomecánica y la estabilidad de la columna y se ha demostrado su intervención en la fisiopatología de las enfermedades de la columna. La evaluación cualitativa de la degeneración muscular se suele realizar analizando la tasa de infiltración de grasa propuesta por el sistema de clasificación de Goutallier. Objetivo:
El objetivo de este estudio es analizar la concordancia intra e interobservador de la Clasificación de Goutallier para evaluar la degeneración grasa del músculo multífido mediante resonancia magnética. Métodos:
Formaron parte del estudio 68 pacientes, todos con diagnóstico de hernia discal sintomática y con indicación quirúrgica. Se utilizaron imágenes de resonancia magnética preoperatorias para el análisis. Las imágenes fueron evaluadas inicialmente por 02 ortopedistas y 02 estudiantes de medicina y, después de dos semanas, reevaluadas. El análisis de fiabilidad intra e interobservador se realizó mediante la prueba Kappa de Fleiss y los criterios de Landis y Koch. Todos los análisis se realizaron utilizando el entorno estadístico R (R Development Core Team, 2016), versión 3.3.1, y el nivel de significancia se estableció en 5%. Resultados:
Los porcentajes de concordancia intra e interobservador fueron, respectivamente, 86,76% y 61,03%. La concordancia intraobservador fue casi perfecta y la concordancia interobservador fue moderada. Conclusión:
el Sistema de Clasificación de Goutallier demostró una moderada concordancia interobservador e intraobservador, siendo una herramienta relevante en la evaluación del reemplazo graso de la musculatura paravertebral. Nivel de evidencia II; Estudio prospectivo con fines diagnósticos.