Prótesis de pivote medial y ultra-congruente: satisfacción y resultados clínicos. Serie de casos
Medial and ultra-congruent pivot designed prosthesis: satisfaction and clinical results. case series
Rev. colomb. ortop. traumatol; 34 (4), 2020
Publication year: 2020
Introducción
La artroplastia total de rodilla es un procedimiento exitoso que mejora significativamente la calidad de vida de los pacientes disminuyendo el dolor e incrementando su capacidad funcional. Sin embargo, la literatura reporta hasta 25% de pacientes insatisfechos. El objetivo de este estudio es presentar los resultados clínicos y la satisfacción de un grupo de pacientes operados con implantes de tipo pivote medial y ultra-congruente.
Materiales y métodos
Se realizó un estudio observacional retrospectivo. Se revisaron las historias clínicas de todos los pacientes operados con los sistemas mencionados con mínimo 12 meses post-operatorios. Se analizaron resultados de 100 rodillas (96 pacientes) que completaron los cuestionarios, con una media de seguimiento de 33.5 meses. Se aplicaron los cuestionarios KSS, KOOS y WOMAC. Se estudiaron diferencias en dolor y función entre la etapa pre-operatoria y el último seguimiento. Se analizó la satisfacción de los pacientes con respecto al dolor y la capacidad funcional. Se evaluaron complicaciones presentadas.
Resultados
Todos los criterios presentaron una mejora estadísticamente significativa entre la etapa pre-operatoria y el último seguimiento. 97% de los pacientes reportaron estar satisfechos con los resultados. Las medias de los cuestionarios fueron entre 83.97 y 95.3. Se presentó 1 caso de revisión por infección peri-protésica.
Discusión
Las prótesis de pivote medial y ultra-congruente constituyen opciones eficaces y seguras para el tratamiento de artrosis de rodilla. Es necesario realizar estudios prospectivos y comparativos que generen evidencia de más alto nivel para confirmar los beneficios de estos diseños.
Background
Total knee arthroplasty is a successful procedure that improves patient quality of life by reducing pain and increasing their functional capacity. However, literature reports up to 25% dissatisfaction in patients. The objective of the study is to present the clinical results and satisfaction of a group of patients operated on using ultra-congruent medial pivot-type implants.
Methods
A retrospective observational study was carried out. The medical records of all the patients who underwent knee arthroplasty surgery with a specific system were reviewed, including patients with a minimum of 12 months follow up. An analysis was performed on the results of 100 knees (96 patients) that had completed questionnaires. There was a mean follow-up of 33.5 months. The KSS, KOOS, and WOMAC questionnaires were used. Differences in pain and function between the pre-surgical stage and the last follow-up were studied. An analysis was made on patient satisfaction with regard to pain and functional capacity. Specific complications were evaluated.
Results
All evaluation criteria showed a statistically significant improvement between the pre-surgical stage and the last follow-up. Almost all (97%) of patients reported being satisfied with the results. The means of the questionnaires were between 83.97 and 95.3. One case of revision due to peri-prosthetic infection was presented.
Discussion
Medial pivot and ultra-congruent prostheses designs are effective and safe options for the treatment of osteoarthritis of the knee. Prospective and comparative studies that generate higher level evidence are necessary to confirm the benefits of these designs.