Actividad física basada en dispositivos versus autorreporte en estudiantes universitarios uruguayos
Device-based monitoring in physical activity versus self-report in Uruguayan university students
Atividade física baseada em dispositivos versus atividade física autorreferida em estudantes universitários uruguaios

Rev. méd. Urug; 38 (2), 2022
Publication year: 2022

Resumen:

Introducción: la medición precisa de la actividad física (AF) es clave para analizar su asociación con resultados de salud. Sin embargo, en Uruguay no existen estudios que comparen diferentes métodos para determinar la AF en adultos. El objetivo de este estudio fue analizar la confiabilidad del Cuestionario Internacional de Actividad Física (IPAQ) en estudiantes universitarios uruguayos y evaluar su validez concurrente en comparación con la AF basada en dispositivos.

Método:

54 estudiantes universitarios de educación física completaron el IPAQ (versión larga) en dos ocasiones con 7 días de diferencia y utilizaron acelerómetros GeneActiv durante ese período. La confiabilidad se evaluó a través del Coeficiente de Correlación Intraclase (ICC) y se utilizó el análisis de Bland-Altman para determinar la validez concurrente.

Resultados:

todos los dominios de AF mostraron niveles moderados de ICC. El transporte (ICC = 0,64), el tiempo libre (ICC = 0,58), y la AF total (ICC = 0,53) fueron los dominios con niveles moderados más altos. El total de minutos de AF evaluados a través del IPAQ en las dos ocasiones reportó un promedio de 773 minutos de diferencia (IC 95% 362,88-1.184,01). La diferencia de minutos de AF entre la evaluación con el IPAQ y con los acelerómetros es de 752 minutos (IC 95% 418,05-1.087.16).

Conclusiones:

el IPAQ sobreestima la AF respecto al acelerómetro en estudiantes universitarios uruguayos, sin embargo fue más confiable al considerar dominios de transporte y tiempo libre para los participantes que reportaron realizar un promedio menor a 400 minutos de AF semanal.

Summary:

Introduction: precise measurement of physical activity (PA) is key to analyze its association with health results. However, there are no studies in Uruguay comparing the different methods to determine PA in adults. The study aims to analyze the reliability of the International Physical Activity Questionnaire (IPAQ) in Uruguayan university students and to assess its validity by comparing it to device-based monitoring PA.

Method:

54 Physical Education university students completed the IPAQ (long version) on 2 occasions with a 7 day difference using GeneActive accelerometers during that period. Reliability was assessed with the Intraclass Correlation Coefficient (ICC) and the Bland-Altman analysis was used to determine concurrent validity.

Results:

all PA domains evidenced moderate ICC levels. Transport (ICC= 0.64), free time (ICC= 0.58) and total PA (ICC= 0.53) were the domains with the highest moderate levels. The total number of minutes of PA assessed by IPAQ reported an average of a 773 minutes difference (CI 95%: 362.88; 1184.01). Difference of PA in minutes, considering the assessment with the IPAQ and the accelerometers is 752 minutes (CI 95%: 418.05; 1087.16).

Conclusions:

the IPAQ overestimates the PA when compared to the accelerometer in Uruguayan university students. However, it was more reliable when considering the transport and free time domains for participants who reported an average physical activity under 400 minutes per week.

Resumo:

Introdução: a mensuração precisa da atividade física (AF) é fundamental para analisar sua associação com desfechos de saúde. No entanto, no Uruguai não existem estudos que comparem diferentes métodos para determinar a AF em adultos.

Objetivo:

analisar a confiabilidade do Questionário Internacional de Atividade Física (IPAQ) em estudantes universitários uruguaios e avaliar sua validade concorrente em comparação com a AF baseada em dispositivos.

Método:

54 estudantes universitários de Educação Física preencheram o IPAQ (versão longa) em 2 ocasiões com 7 dias de intervalo e usaram acelerômetros GeneActiv durante esse período. A confiabilidade foi avaliada por meio do Coeficiente de Correlação Intraclasse (ICC) e a análise de Bland-Altman foi utilizada para determinar a validade concorrente.

Resultados:

todos os domínios da AF apresentaram níveis moderados de ICC. Transporte (ICC = 0,64), tempo livre (ICC = 0,58) e AF total (ICC = 0,53) foram os domínios com os níveis moderados mais altos. O total de minutos de AF avaliados pelo IPAQ em ambas as ocasiões apresentou diferença média de 773 minutos (IC 95%: 362,88; 1184,01). A diferença em minutos de AF entre a avaliação com o IPAQ e com os acelerômetros é de 752 minutos (IC 95%: 418,05; 1087,16).

Conclusões:

o IPAQ superestima a AF em relação ao acelerômetro em universitários uruguaios, porém, foi mais confiável ao considerar os domínios transporte e tempo livre para participantes que relataram realizar em média menos de 400 minutos de AF por semana.

More related