Introducción:
Para el reemplazo de válvula aórtica con catéteres (TAVR) es fundamental la adecuada medición del anillo aórtico para elegir el tamaño adecuado de la prótesis y evitar complicaciones graves como la ruptura del anillo aórtico y la insuficiencia paravalvular (IAP). La tomografía computada cardíaca (TC) es el estándar de oro en la medición del anillo aórtico, pero la ecocardiografía transesofágica 3D (ETE3D) parece ser una alternativa atractiva.Objetivo:
Evaluar la correlación entre las mediciones del anillo aórtico obtenidas por ETE3D y las encontradas en la TC. Los resultados obtenidos se evaluaron en términos de la prótesis elegida y la presencia de insuficiencia aórtica post TAVR.Métodos:
Se realizaron de manera retrospectiva y ciega, las mediciones del anillo aórtico por TC y ETE3D en 18 pacientes consecutivos, edad promedio 82 ± 7,06 años, sometidos a TAVR usando prótesis Sapien XT (Edwards Lifescience). Se comparó el diámetro máximo, diámetro mínimo, diámetro medio, área y perímetro del anillo.Resultados:
La ETE3D subvaloró el tamaño del anillo aórtico, pero demostró tener una buena correlación con los diferentes parámetros de la TC, con mejor comportamiento para el perímetro del anillo. ETE3D y TC coincidieron en la elección de la prótesis en 17 pacientes y no hubo IAP de relevancia.Conclusión:
La ETE3D tiene buena correlación comparada contra la TC en la valoración del anillo aórtico. La ETE3D parece una atractiva alternativa a la TC para medición del anillo especialmente en casos complejos o cuando la disponibilidad y acceso a la TC puede estar limitada.
In TAVR, the precise measuring of the aortic annulus is essential to determine the size of the prosthesis and to avoid complications like rupture of the annulus of aortic insufficiency. Computed tomography (CT) is the gold standard to achieve these goals. 3-D trans-esophageal echocardiography (3-D TEE) to be a useful alternative method.
Aim:
to evaluate the correlation of aortic annulus measurements obtained with 3-dTE and CT in the determination of annulus measurements before TAVR. Prosthesis size and presence of aortic insufficiency were related to these measurements.Methods:
In a retrospective blinded protocol the measurements of the aortic annulus obtained with CT or 3D-TEE were correlated in 18 consecutive patients (mean age 82 ± 7.1) submitted to TAVR with a Sapien XT (Edwards Lifescience) prosthesis. Maximal, minimal and mean diameters as well as area and annular circumference were evaluated.Results:
Compared to CT, 3D-TEE under estimated de size of the aortic annulus but correlated well with other measurements of CT, especially with the annular circumference. Measurements from both methods agreed in the determination of the prosthesis size in 17 of 18 patients. No significant per prosthetic aortic insufficiency was observed in any case.Conclusion:
3DTEE correlates well with CT in evaluating the different parameters of the aortic annulus and is a good alternative to CT in complex cases and when CT is not readily available.
Tomografía Computarizada Multidetector/métodos, Válvula Aórtica/diagnóstico por imagen, Estenosis de la Válvula Aórtica/diagnóstico por imagen, Estenosis de la Válvula Aórtica/terapia, Ecocardiografía Tridimensional/métodos, Estudios Retrospectivos, Reemplazo de la Válvula Aórtica Transcatéter/métodos, Ecocardiografía Transesofágica/métodos, Cuidados Preoperatorios, Diseño de Prótesis