Predicciones de la entropía proporcional en la dinámica cardíaca
Predictions of proportional entropy in cardiac dynamics
Previsões de entropia proporcional na dinâmica cardíaca

Rev. MED; 23 (2), 2015
Publication year: 2015

Antecedentes:

A partir de la teoría de sistemas dinámicos se desarrolló una metodología que permite diferenciar dinámicas cardíacas normales, en distintos niveles de enfermedad y en evolución entre estos estados. Esto se hizo cuantificando en el espacio de fases, mediante la entropía y sus proporciones, la probabilidad de parejas ordenadas de frecuencias cardiacas.

Objetivo:

Aplicar clínicamente la metodología desarrollada a 400 dinámicas cardíacas para establecer su efectividad comparándola con el diagnóstico clínico convencional.

Método:

Se tomaron Holters de 400 individuos; 50 diagnosticados como normales y 350 con diferentes patologías. Para cada uno se construyó un atractor en el mapa de retardo y se evaluó, mediante la entropía y sus proporciones, la probabilidad de ocupación de pares ordenados de frecuencias cardíacas durante 18 horas. Se compararon las medidas obtenidas con los valores de normalidad y enfermedad establecidos previamente para obtener el diagnóstico de cada Holter. Las conclusiones del Holter y los antecedentes clínicos sólo fueron desenmascarados luego de haber aplicado la metodología físico-matemática para calcular sensibilidad, especificidad y coeficiente Kappa respecto al Gold-Estándar.

Resultados:

con las proporciones de la entropía de los atractores se diferenciaron dinámicas cardíacas agudas, crónicas, normales, y evolución normalidad-enfermedad. Se confirmó la aplicabilidad clínica de la metodología predictiva desarrollada para el Holter, que mostró una sensibilidad y especificidad del 100%. La concordancia entre el Gold-Estándar y el diagnóstico físicomatemático fue 1.

Conclusiones:

La aplicación de la metodología permitió establecer cuantitativamente estados de normalidad y enfermedad de la dinámica cardíaca, evidenciando una auto-organización del atractor dinámico geométrico que constituye un método de ayuda diagnóstica aplicable a la clínica.
Based on dynamic systems theory, a methodology that allows to differentiate normal cardiac dynamics, different levels of abnormality and evolution between these states, was developed. This was done by quantifying the probability of ordered pairs of heart rates in the phase space, through entropy and its proportions. To apply in a clinical setting the developed methodology to 400 cardiac dynamics in order to establish its effectiveness by comparing it with the conventional diagnosis. Holters from 400 individuals were tested for a minimum of 18 hours; 50 with normal diagnosis and 350 with different pathologies. An attractor was built for each one of them in the delay map, and the occupation probability of ordered pairs of heart rates was evaluated through entropy and its proportions. Afterwards, results were compared with values of normality and disease previously established to obtain the diagnosis for each Holter. The findings of Holter and medical history were only revealed after applying the physical-mathematical methodology, in order to calculate sensitivity, specificity and Kappa coefficient regarding to the Gold-Standard. With the entropy proportions of the attractors, acute cardiac dynamics were differentiated from chronic and normal ones, as well as the evolution between normality and disease. A clinical application of the predictive methodology for Holter was developed. Sensitivity and specificity were both 100% and the correlation between the Gold-Standard and the physical-mathematical diagnosis was 1. The application of the methodology allowed establishing quantitatively states of normality and disease of the cardiac dynamic, showing a self-organization of the geometrical dynamic attractor.

Antecedentes:

A partir da teoria de sistemas dinâmicos se desarrolho uma metodologia que permite diferenciar dinâmicas cardíacas normais, em distintos niveles de doença e na evolução entre estes estados, o qual foi realizado quantificando no espaço de fases a probabilidade de pares ordenados de frequências cardíacas, através da entropia e as suas proporções.

Objetivo:

Aplicar clinicamente a metodologia desenvolvida a 400 dinâmicas cardíacas para estabelecer sua eficácia comparada com o diagnóstico clínico convencional.

Método:

Se tiraram Holters de 400 pessoas, 50 deles foram diagnosticados como normais e 350 têm diferentes patologias. Um atractor no mapa de retardos foi construído para cada um deles e, através da entropia e as suas proporções, a probabilidades de ocupação de pares ordenados de frequências cardíacas durante 18 horas foi avaliada. Além disso, as medidas obtidas foram comparadas com os valores de normalidade e doenças estabelecidas previamente para obter o diagnostico de cada Holter. As conclusões do Holter e os antecedentes clínicos somente foram descobertos logo de aplicar a metodologia físico-matemática para calcular a sensibilidade, especificidade y coeficiente Kappa acerca do Padrão-Ouro (Gold-Standard).

Resultados:

As dinâmicas cardíacas agudas, crônicas, normais y a evolução da normalidade e as doenças foram diferenciadas pelas proporções da entropia dos atractores. Confirmou-se a aplicabilidade clínica da metodologia preditiva desenvolvida para o Holter, a qual demonstrou uma sensibilidade e especificidade de 100%. O acordo entre o Padrão-Ouro (Gold-Standard) e o diagnóstico físico-matemático foi 1.

Conclusões:

A aplicabilidade da metodologia permitiu estabelecer quantitativamente estado de normalidade e doenças da dinâmica cardíaca, mostrando uma auto-organização do atrator dinâmico geométrico que constitui um método de ajuda diagnostica aplicável à clínica.

More related