Stent-graft relining in a patient with acute aortic aneurysm and a completely migrated endograft
Rev. bras. cir. cardiovasc; 32 (6), 2017
Publication year: 2017
Abstract Stent-graft migration and type I endoleaks are associated with a higher rate of reintervention and increased mortality and morbidity. This article describes a patient presented with an infrarenal aortic stent-graft which had migrated into the aortic sac with loss of all aortic neck attachment. The acutely expanding abdominal aortic aneurysm was treated by placing a second modular endograft within and above the migrated stentgraft. The patient returned 36 months later, with features of an acute myocardial infarction, severe bilateral lower limb ischemia, and renal failure. He was too ill for intervention and demised within 48 hours.
Aorta Abdominal/cirugía, Aneurisma de la Aorta Abdominal/cirugía, Implantación de Prótesis Vascular/efectos adversos, Procedimientos Endovasculares, Resultado Fatal, Migración de Cuerpo Extraño/diagnóstico por imagen, Migración de Cuerpo Extraño/cirugía, Complicaciones Posoperatorias, Stents/efectos adversos, Tomografía Computarizada por Rayos X