Publication year: 2018

Abstract This study aimed to evaluate the physicochemical properties of a calcium silicate-based sealer (Sealer Plus BC; MK Life, Porto Alegre, Brazil) compared with an epoxy-resin sealer (AH Plus; Dentsply DeTrey GmbH, Konstanz, Germany).

Initial and final setting time was assessed based on ISO 6876:

2012 and ASTM C266:03. Calcium ion release and pH were evaluated by filling polyethylene tubes with sealers and then immersing them in 10 mL of deionized water. Following experimental periods of 1, 24, 72 and 168 hours, the samples were measured regarding pH and calcium ion release with a pH meter and a colorimetric spectrophotometer, respectively.

The flow was examined based on ISO 6876:

2012. Rings of 10 mm in diameter with 1 mm thickness were prepared to analyze the radiopacity (ISO 6876:2012 and ADA n.57) and solubility (ISO 6876:2012). The data were analyzed by variance analysis, Student-T and Tukey tests (p<0.05). The calcium ion release and pH values were significantly higher for the Sealer Plus BC compared with the AH Plus (p<0.05). Lower setting time, flow and radiopacity were observed for the bioceramic sealer than for AH Plus (p<0.05). Sealer Plus BC exhibited higher solubility compared with AH Plus (p<0.05). Sealer Plus BC showed physicochemical properties as setting time, pH, calcium release, flow, and radiopacity following the required standards, but higher solubility than the minimum values required by ISO 6876:2012.
Resumo Este estudo teve por objetivo avaliar as propriedades físico-químicas de um cimento à base de silicato de cálcio (Sealer Plus BC MK Life, Porto Alegre, Brasil) e compará-las a um cimento à base de resina epóxica (AH Plus, Dentsply DeTrey GmbH, Konstanz, Alemanha).

Tempo de presa inicial e final foram avaliados com base na ISO 6876:

2012 e ASTM C266:03. Liberação de íons cálcio e pH foram avaliados após o preenchimento de tubos de polietileno com os cimentos e imersão em 10 mL de água deionizada. Após os tempos experimentais de 1,24,72 e 168 horas, os valores de pH e liberação de íons cálcio foram mensurados utilizando um medidor de pH e um espectofotômetro colorimétrico, respectivamente.

Escoamento foi avaliado com base na ISO 6876:

2012. Moldes de 10 mm de diâmetro e 1 mm de espessura foram preparados para análise de radiopacidade (ISO 6876:2012 e ADA n.57), solubilidade (ISO 6876:2012). Os dados foram analisados por análise de variância, teste T de Student e teste de Tukey (p<0,05). A liberação de íons cálcio e os valores de pH foram significativamente maiores para o Sealer Plus BC em comparação com o AH Plus (p<0,05). Menores valores de tempo de presa, escoamento e radiopacidade foram observados para o cimento biocerâmico quando comparados com o AH Plus (p<0,05). Sealer Plus BC apresentou propriedades físico-químicas de tempo de presa, pH, liberação de íons cálcio, escoamento, radiopacidade de acordo com as normas exigidas, porém maior solubilidade que aquelas previstas pela ISO 6876:2012.

More related