Left ventricular aneurysm repair: off-pump linear plication versus on-pump patch plasty
Rev. bras. cir. cardiovasc; 34 (2), 2019
Publication year: 2019
Abstract Objective:
The study aimed to compare the clinical outcomes of simplified linear plication and classic patch plasty in patients with left ventricular aneurysm (LVA).Methods:
We retrospectively reviewed 282 patients undergoing LVA repair between 2006 and 2016. After propensity score matching, 45 pairs of patients receiving LVA surgery were divided into either a patch group (on-pump endoventricular patch plasty) or a plication group (off-pump linear plication). Then, their early surgical outcomes and long-term survival were compared in two matched groups.Results:
The heart function improvement at discharge was similar in the two matched groups, while patients in the patch group more commonly suffered from low cardiac output syndrome (P=0.042) with higher proportion of intra-aortic balloon pumping assistance (P=0.034) than patients in the plication group. Compared with patients in the patch group, the patients in the plication group had shorter recovery times, regarding to mechanical ventilation, intensive care unit stay, and hospital stay (P<0.001, P<0.001, and P=0.001, respectively). No significant difference was found in the long-term survival (P=0.62).Conclusions:
Off-pump linear plication presented acceptable results in terms of early outcomes and long-term survival. For high-risk patients, the simplified LVA repair technique may be an option.
Estudios de Seguimiento, Aneurisma Cardíaco/mortalidad, Aneurisma Cardíaco/cirugía, Ventrículos Cardíacos/cirugía, Tiempo de Internación, Ilustración Médica, Puntaje de Propensión, Valores de Referencia, Estudios Retrospectivos, Factores de Riesgo, Estadísticas no Paramétricas, Análisis de Supervivencia, Factores de Tiempo, Resultado del Tratamiento