Publication year: 2014
Theses and dissertations in Español presented to the Universidad Nacional Mayor de San Marcos. Facultad de Medicina to obtain the academic title of Especialista. Leader:
Objetivo:
Determinar las respuestas hemodinámicas en la intubación endotraqueal con el uso del videolaringoscopio C-MAC versus laringoscopio Macintosh en colecistectomía laparoscópica en el Hospital Nacional Luis N. Sáenz PNP, durante marzo a mayo del 2014. Metodología:
Estudio observacional, analítico-comparativo, prospectivo de corte longitudinal. En el estudio participaron 53 pacientes, de los cuales a 27 pacientes se les realizó intubación endotraqueal con videolaringoscopio C-MAC y 26 pacientes fueron intubados con el laringoscopio Macintosh. Para el análisis descriptivo se empleó medidas de tendencia central y de dispersión, así como, frecuencias absolutas y relativas. Para el análisis bivariado se empleó la prueba del Chi-cuadrado y "t" student, con nivel de confianza del 95 por ciento. Resultados:
Las características generales de los pacientes con intubación endotraqueal fueron de sexo masculino en el 71.7 por ciento, y tuvieron sobrepeso en el 75.5 por ciento. Al evaluar la respuesta hemodinámica con el C-MAC, se observó PAM (Presión arterial media) basal 76,2±5,6 mmHg, en la postinducción por influencia del anestésico se observa disminución hasta 66±8,9 mmHg para luego incrementarse en la laringoscopía (73,8±17,3 mmHg) y en el momento posterior a la IET (76,6±12,3 mmHg), a partir de los 3 minutos de la IET empieza a descender; en cuanto a la Frecuencia cardiaca (FC) ocurre el mismo efecto pues disminuye en la postinducción (58,1±6,6 1pm) para luego incrementarse en la laringoscopía (67,6±11,8 lpm) y al momento de la postinducción (66±8.9 mmHg), a partir de los 3 minutos de la IET empieza a descender. La respuesta hemodinámica con el uso de Macintosh fue:
PAM basal 73,2±7 mmHg, disminuyó en la postinducción (60,1±4,6 mmHg), se incrementa en la laringoscopía (67±7,3 mmHg) y en el momento posterior a la JET (77,1±7 mmHg) luego desciende a partir de los 3 minutos de la IET; respecto a la FC se incrementa en la laringoscopía (65,4±5,3 lpm) y en el...
Objective:
To determine the hemodynamic responses in endotracheal intubation using the C-MAC video laryngoscope versus Macintosh laryngoscope in laparoscopic cholecystectomy at the National Hospital Luis Saenz N. PNP during March to May 2014. Methodology:
Observational, analytical-comparative, prospective, transversal study. The sample was 53 patients, of which 27 underwent endotracheal intubation with C-MAC video laryngoscope and 26 patients were intubated with the Macintosh laryngoscope. For the descriptive analysis, measures of central tendency and dispersion were used, as well as absolute and relative frequencies. For bivariate analysis, it was used the chi-square test and "t" student, with a confidence level of 95 per cent. Results:
The general characteristics of patients with endotracheal intubation were male in 71.7 per cent and were overweight in 75.5 per cent. In assessing the hemodynamic response with C-MAC, it was found basal MAP (mean arterial pressure) 66±8.9 mmHg, in the post-induction under the influence of anesthetic was observed decrease up to 66±8.9 mmHg to later increased in laryngoscopy (73.8±17.3 mmHg) and the time after the EIT (76.6± 12.3 mmHg), after 3 min of EIT begins to descend; about heart rate (HR) occurs the same effect, as it decreases in the post-induction (58.1±6.6 bpm) to later increased in laryngoscopy (67.6±11.8 bpm) and at the time of post-induction (66±8.9 mmHg), after 3 minutes of the EIT begins to descend. The hemodynamic response with the use of Macintosh was:
basal MAP 73.2±7 mmHg, decreased in the post-induction (60.1±4.6 mmHg), increased in laryngoscopy (67±7.3 mmHg) and after EIT (77.1±7 mmHg); then descends starting from 3 minutes of the EIT; regarding the HR, it increases in laryngoscopy (65.4±5.3 bpm) and after EIT (76.4±5 bpm) to later descend to 3 minutes from the EIT. Applying statistical analysis "t" student was observed significant difference in the hemodynamic response to mean arterial pressure at the time...