ABSTRACT Topography-guided ablation was designed to improve corneal regularity throughout the correction of corneal high order aberrations. The present report described three cases with different indications for topography-guided ablation to correct irregular astigmatism. The patients were monitored in t...
Trasplante de Córnea/efectos adversos,
Queratectomía Fotorrefractiva/efectos adversos,
Queratocono/complicaciones,
Astigmatismo/diagnóstico,
Astigmatismo/etiología,
Astigmatismo/patología,
Astigmatismo/cirugía,
Córnea/patología,
Córnea/cirugía,
Topografía de la Córnea/métodos,
Refracción Ocular/fisiología,
Monitoreo Intraoperatorio/métodos,
Agudeza Visual
RESUMO Objetivo: Avaliar retrospectivamente a influência da espessura do anel intracorneano na redução do astigmatismo corneano em pacientes portadores de ceratocone. Métodos: De um banco de dados com 2.033 olhos submetidos à cirurgia de implante de anel corneano, foi selecionada uma amostra de 90...
RESUMO O implante de lentes intraoculares fácicas com finalidade refrativa é uma alternativa cirúrgica eletiva segura e eficiente. Essa opção deve ser considerada de forma eletiva para tratar ametropias, nos casos em que as cirurgias de correção visual refrativa a laser na córnea apresentam maior...
ABSTRACT Purpose: To investigate the impact of different sizes of steep meridian clear corneal incisions for phacoemul sification on anterior corneal higher-order aberrations. Methods: Medical records of patients who underwent 2.2-mm coaxial micro-incision cataract surgery or 2.75-mm coaxial small-inci...
Astigmatismo,
Extracción de Catarata,
Catarata,
Facoemulsificación,
Astigmatismo/etiología,
Astigmatismo/cirugía,
Córnea/cirugía,
Topografía de la Córnea,
Implantación de Lentes Intraoculares,
Facoemulsificación/efectos adversos,
Estudios Retrospectivos
ABSTRACT Purpose: We aimed to evaluate the visual quality performance of scleral contact lenses in patients with keratoconus, pellucid marginal degeneration, and post-keratoplasty astigmatism, and their impact on quality of life. Methods: We included 40 patients (58 eyes) with keratoconus, pellucid mar...
RESUMO Relatamos um caso de astigmatismo residual, após cirurgia de catarata com implante de lente intra-ocular (LIO) tórica (Acrysof Toric, Alcon, Frot Worth TX). A refração residual (+1,25 -2,50 x 105º) e o posicionamento da LIO implantada neste olho, foram correlacionados com a aberrometria total...
Astigmatismo/etiología,
Astigmatismo/cirugía,
Lentes Intraoculares/efectos adversos,
Implantación de Lentes Intraoculares/efectos adversos,
Complicaciones Posoperatorias,
Facoemulsificación,
Aberrometría,
Informes de Casos,
Catarata,
Agudeza Visual,
Refracción Ocular/fisiología,
Microscopía con Lámpara de Hendidura,
Rotación/efectos adversos,
Reoperación,
Astigmatismo/diagnóstico
Abstract We present a case of a 12-year-old patient with advanced keratoconus in both eyes who received a two-staged treatment in the right eye (OD) to decrease keratoconus progression rate and rehabilitate patient's vision. At the initial clinical examination, visual acuity without correction in OD was ...
Queratocono/diagnóstico,
Queratocono/cirugía,
Agudeza Visual,
Topografía de la Córnea,
Paquimetría Corneal,
Microscopía,
Sustancia Propia/cirugía,
Prótesis e Implantes,
Implantación de Prótesis/métodos,
Refracción Ocular,
Astigmatismo/cirugía,
Tomografía de Coherencia Óptica,
Biometría,
Cámara Anterior/cirugía,
Implantación de Lentes Intraoculares/métodos,
Lentes Intraoculares Fáquicas
OBJECTIVES: To describe the indications for and visual outcomes of intrastromal corneal ring segment implantation. METHODS: A large retrospective case-series chart-review study was conducted using Sorocaba Ophthalmological Hospital medical records. This study included 1222 eyes (1196 patients) that were...
Astigmatismo/cirugía,
Edema Corneal/cirugía,
Sustancia Propia/patología,
Sustancia Propia/cirugía,
Queratocono/cirugía,
Prótesis e Implantes,
Implantación de Prótesis,
Estudios Retrospectivos,
Índice de Severidad de la Enfermedad,
Resultado del Tratamiento,
Agudeza Visual
Resumo O objetivo deste artigo foi reunir estudos que reportam resultados disponíveis na literatura científica, considerando a previsibilidade, segurança, eficácia, e estabilidade das lentes intraoculares fácicas de câmara posterior. E relatar as complicações documentadas para estas lentes. A rev...
Implantación de Lentes Intraoculares/métodos,
Lentes Intraoculares Fáquicas,
Errores de Refracción,
Procedimientos Quirúrgicos Refractivos/métodos,
Miopía/cirugía,
Hiperopía/cirugía,
Astigmatismo/cirugía,
Segmento Posterior del Ojo/cirugía,
Resultado del Tratamiento,
Complicaciones Posoperatorias,
Refracción Ocular/fisiología
ABSTRACT Purpose: To report the visual rehabilitation outcomes and complications of patients fitted with mini-scleral rigid gas-permeable (RGP) contact lenses (mini-SCLs) after penetrating keratoplasty. Methods: We retrospectively reviewed 27 eyes (21 patients) that were fitted with mini-SCLs between O...
Astigmatismo/complicaciones,
Astigmatismo/cirugía,
Lentes de Contacto/efectos adversos,
Queratitis/rehabilitación,
Queratocono/cirugía,
Queratoplastia Penetrante/efectos adversos,
Queratoplastia Penetrante/rehabilitación,
Complicaciones Posoperatorias,
Estudios Retrospectivos,
Factores de Tiempo,
Resultado del Tratamiento,
Agudeza Visual