Results: 100

Patrón de Brugada: Estratificación del riesgo de muerte súbita
Brugada pattern: Risk stratification of sudden death

Rev. méd. hered; 29 (1), 2018
El síndrome de Brugada ha sido relacionado históricamente a muerte súbita; sin embargo, el diagnóstico y estimación de riesgo puede ser impreciso y variable en razón a los factores de riesgo cardiovascular, comorbilidad y evolución clínica inesperada. Se presenta el caso de un varón de 72 años ...

Subcutaneous implantable cardioverter defibrillator: early experience

Abstract Introduction: The implantable cardioverter defibrillator had been increasing the survival of patients at high risk for sudden cardiac death. The subcutaneous implantable cardioverter defibrillator was developed to mitigate the complications inherent to lead placement into cardiovascular system....

Predictors of Total Mortality and Echocardiographic Response for Cardiac Resynchronization Therapy: A Cohort Study

Arq. bras. cardiol; 109 (6), 2017
Abstract Background: Clinical studies demonstrate that up to 40% of patients do not respond to cardiac resynchronization therapy (CRT), thus, appropriate patient selection is critical to the success of CRT in heart failure. Objective: Evaluation of mortality predictors and response to CRT in the Brazil...

Taquicardia ventricular como expresión de distrofia miotónica tipo 1

Rev. chil. cardiol; 36 (3), 2017
Abstracts: A 48-year-old woman was brought to the emergency room with ventricular tachycardia that was eventually terminated by cardioversion. Clinical and neurologic evaluation, including electromyography were highly suggestive of type I Myotonic Dystrophy and genetical studies confirmed the diagnosis. ...

Sucesso na remoção percutânea de cabos-eletrodos endocárdicos implantados ha 18 anos utilizando ferramentas de extração

Infecções relacionadas aos dispositivos eletrônicos cardíacos exigem sua completa remoção, sendo necessário o conhecimento das técnicas percutâneas de extração de cabos-eletrodos, evitando-se, assim, a cirurgia cardíaca com esternotomia e bypass cardiopulmonar. Apresentamos o caso de paciente...

Effectiveness of implantation of cardioverter-defibrillators therapy in patients with non-ischemic heart failure: an updated systematic review and meta-analysis

Abstract Objective: Implantable cardioverter-defibrillator has become the first-line therapy for prevention of sudden cardiac death. Controversial results still exist regarding the effectiveness of implantable cardioverter-defibrillator (ICD) in non-ischemic heart failure. Methods: The PubMed, Embase, ...

Non-Sustained Ventricular Tachycardia Episodes Predict Future Hospitalization in ICD Recipients with Heart Failure

Arq. bras. cardiol; 109 (4), 2017
Abstract Background: Implantable cardioverter-defibrillator (ICD) therapy is well known to reduce mortality in selected patients with heart failure (HF). Objective: To investigate whether monitored episodes of non-sustained ventricular tachycardia (NSVT) might predict future HF hospitalizations in ICD ...

Papel da ressonância magnética nuclear cardíaca na terapia de ressincronização cardíaca

A insuficiência cardíaca é um importante problema de saúde pública. As modificações cardíacas estruturais que surgem com o processo de cronificação da insuficiência cardíaca levam a anormalidades na contração miocárdica e à dessincronização ventricular. A terapia de ressincronização c...

Falha do teste desfibrilatório associado a posicionamento do cabo-eletrodo de choque no septo do ventrículo direito

O teste de desfibrilação, durante muitos anos, foi prática comum no momento do implante de cardiodesfibrilador. Após o estudo Shockless Implant Evaluation (SIMPLE), que não evidenciou redução da eficácia e da segurança do cardiodesfibrilador a longo prazo com a não realização do teste de desf...

Interferência eletromagnética documentada em monitor de eventos implantável

Monitores de eventos implantáveis estão cada vez mais presentes em nossa realidade. Este relato tem como foco o registro eletrocardiográ- fico obtido por monitor de eventos implantável durante ressonância magnética de paciente com síncope de repetição. O registro demonstra traçado interpretado ...