Results: 7

Evaluation of Masticatory Performance and Patient Satisfaction Before and After Posterior Implant Restoration

ABSTRACT Objective: To evaluate the improvement in masticatory performances two weeks after posterior implant restoration. Material and Methods: Nine patients with missing first and second molars were included in the study. Masticatory performances were evaluated using subjective and objective methods ...

Reliability of Linear and Curvilinear Measurements on Cone-Beam Computed Tomography Images for the Evaluation of Implant Sites and Jaw Pathologies

ABSTRACT Objective: To evaluate the intra-examiner and inter-examiner reliability of linear and curvilinear measurements for the complete assessment of implant sites and jaw pathologies using Cone-Beam Computed Tomography (CBCT). Material and Methods: Fifty cone-beam computed tomographic images of pati...

Evaluation of the long-term stability of micro-screws under different loading protocols: a systematic review

Abstract: The aim of this systematic review was to investigate the association between the different factors of loading protocols and the long-term stability of micro-screws from biomechanical and histological viewpoints. Searches were performed on PubMed, Embase, Cochrane Library, Wanfang and CNKI datab...

Mini-implant selection protocol applied to MARPE

Abstract Introduction: Rapid maxillary expansion (RME) is the therapy of choice to correct skeletal transverse dimension in children and adolescents, associating orthopedic and dental effects. In an attempt to prevent the undesirable dentoalveolar effects and optimize the potential of skeletal expansion...

Study of the relationships between bur diameter and dental implant diameter

The bur used to construct the bed where a dental implant is installed is extremely important to treatment success. The aim of this investigation was to analyze the relationship between bur diameter and implant diameter in different areas. A descriptive study was designed to analyze 5 commercial brands cu...

Accuracy of resonance frequency analysis by third generation Osstell®

The Resonance Frequency Analysis by Osstell® is used in the assessment of primary and secondary implant stability. The aim of this study was to determine its accuracy as a method of testing, checking its repeatability and reproducibility. A pilot study was performed whereby implants were placed in a cow...

Rehabilitación sobre implantes oseointegrados
A case with rehabilitation on boneintegrated implants

Rev. cuba. estomatol; 46 (1), 2009
Se presenta un caso de un paciente rehabilitado en la consulta de Implantología de la Facultad de Estomatología de Ciudad de La Habana. La historia de la implantología moderna se remonta a principios de los años 60, cuando Per-Ingvar Branemark sienta las bases de la osteointegración y describe los p...